Aportamos valor para proporcionar energia al mundo

PREVENTIVE CHEMICAL CLEANING

GDES nuclear services carry out the preventive chemical cleaning operation in the PWR steam generators.

Aim of this project was to formulate and develop a chemical cleaning procedure that significantly reduces the obstruction level generated by the presence of magnetite in the PWR steam generators.

 

  • Qualification: 2010 – 2013
  • First intervention: CNPE Dampierre 1 (2013)
  • Last intervention: CNPE Dampierre 2 (2016)

 

Chemical cleaning procedure developed by GDES. IT is intended to dissolve at least 200 kg of deposits by steam generator with the objective of 500 kg and with a maximum corrosion of 100 μm over carbon steel.

PACCO procedure is a preventive chemical cleaning process that consists of two stages:

 

  • Partial magnetite deposits removal at low temperature (between 30-40ºC) by combination of weak organic acids and Nitrogen sparging.
  • Elimination of metallic copper (initially present in the deposits or resulting from copper-plating phenomenon occurred during the acid phase).

 

GDES_Servicios_nucleares_limpiezas químicas